Profibus DP Redundant Link Module,RLM01
EN
产品分类
RLM Redundant Link Module首页 >FieldBus > RLM Redundant Link Module
Ci-PP21 series (RLM)|Profibus DP Redundant Link Module,RLM01
1/10
上一个
下一个
Ci-PP21 series (RLM)
系列描述:Profibus DP Redundant Link Module,RLM01

* Support 3 Profibus DP bus, according to Profibus DP Protocol
* Realizes the mutual conversion between single bus (M port) and dual redundant bus (A, B port)
* Support Dial switch for setting communication rate(all ports baud rate must be same)
* Support 3Chs photon coupled isolation ports, Isolated Voltage 1000V, and 4000V Anti-thunder protection
* Support 4 dual colors LED Indicator, Fieldbus ports error Relay alarm output
* DC (9~36V) dual redundant power input, With DC 1500V voltage isolation and reverse connect protection
* IP40 protection, Metal case (wave grain aluminum reinforce case option), 35mmDIN-Rail Installation
* Operating Temperature: -40℃ to 75℃ suitable to various Industrial work situation

  • 产品概述
  • 规格参数
  • 尺寸外观
  • 文档下载
  • 订购参数
  • 行业应用
         This series is designed for industrial grade Profibus DP Link Redundant Module, support Profibus DP protocol. The link redundancy module realizes the mutual conversion between single bus (M port) and dual redundant bus (A, B port), either converting the single cable bus  to a redundant Profibus DP bus, or the redundant Profibus DP bus to a single cable bus. The data received from the M port is broadcast to the A, B port, but the A or B port data is forwarded to the M port in the first selection principle, so as to establish a working path at any time, monitoring the state of communication equipments in real-time. When the receiver at the port of the operation detects a bus fault, switch to the redundant port, and vice versa. The device can be directly placed after the Profibus DP master, the single cable bus into a redundant bus; can also be placed on the slave bus to convert the redundant bus to non-redundant cable, with optocoupler isolation, reduce interference and other performance , The rate set by the DIP switch or select the rate of adaptive settings.The product is Industrial grad designed, Casing: IP40 protection, wave grain aluminum reinforce case option, DIN rail mounting, DC (9~36V) power input, support Fieldbus ports error Relay alarm output, dual redundant power input and isolation protection. -40~75℃Operating Temperature, can meet various Industrial situation.
    Bus data interface
    * Interface type: standard 9 pin type D Profibus DP fieldbus cable interface, conform to Profibus DP protocol standard.
    * Support Profibus DP bus standard
    * Baud Rates: 9.6Kbps、19.2 Kbps、45.45Kbps、93.75Kbps、187.5Kbps、500Kbps、1.5Mbps、6Mbps 、12Mbps
    * Signal Delay (electrical interface): ≤4Bit
    * Isolated voltage 1000V,4000V Anti-thunder protection
    * Resistor: without terminal resistor, connect external when necessary

    Power
    * DC (9~36V) dual redundant power input, industrial standard voltage DC 24V, consumption is less than 4W, With DC 1500V voltage isolation and reverse connect protection, adopt 5 cores 5.08mm industrial terminal port (please use industrial standard power, otherwise it will occur unit error or damage).

    Protection
    * Relay: Fieldbus ports error Relay alarm output
    * Contact rating: 1A @24V DC, Industrial Terminal port

    Mechanical
    * Dimensions (H×D×W): 136mm×104.8mm×52.8mm
    * Weight:800g
    * Casing: IP40 protection, wave grain aluminum reinforce case option
    * Installation: Wall mounting or DIN rail mounting

    Environmental
    * Operating Temperature:-40℃~75℃(-40℃~85℃ optional)
    * Storage Temperature: -40℃~85℃
    * Ambient Relative Humidity: 5%~95%(non-condensing)

    Warranty
    * Warranty Period: 5 years

    Certification
    * IEC61000-4-2(ESD): Power ±2KV Contact, ±15KV Air; Relay ±2KV Contact, ±15KV Air; Data Cable ±15KV Air
    * IEC61000-4-4(EFT):Power ±4KV, Data Cable ±4KV
    * IEC61000-4-5(Surge):Power ±2KV CM/ ±1KV DM, Relay±2KV CM/ ±1KV DM
    * IEC60068-2-27(Shock)
    * IEC60068-2-32(Free Fall)
    * IEC61000-6-2(General Industrial Standard)
    * EN50121-4 (rail transit)

    选择产品型号描述
    Ci-PP21Profibus bus link redundancy module, 1 M port (DP3), 2 redundant bus A (DP1), B (DP2) port, DIP switch setting rate or rate adaptive option.
    
    服务热线:
    400-863-2699联系我们
    首页|工业交换机|工业总线|解决方案|技术支持|新闻中心|关于我们|联系我们

    深圳市讯记科技有限公司

    总机: (0755) 26055466 ; 26055499 ; 26653931
    免费服务热线:400-863-2699
    邮箱: support@comark.cn
    地址: 广东·深圳市宝安区西乡街道固戍社区西井路21号塘西第二工业区G栋4层